VXP Premium

NoBurn XP Premium Fire Perpormance Cable, certified and Approved LPCB to meet BS EN 50200:2015+ANNEX E 30 mins, BS EN 50200:2015 PH30, PH60 & PH120 and BS 6387:2013 CWZ-under fire condition. Cable Core are twisted, Tray Fastening Metal Tie & spacing every 1.5 meters.   Tested and Complies with: Fire Resistance Standard        … Read more

VNP-325

Enhanced- 3 Core 2.5 mm² with Earth (CPC), Harmonised Insulation Colour (Blue/Brown), Sheath (White)   Approved and certified to meet:   BS 5839-1 Clause 26.2e BS 7629-1 Enhanced 120 BS 8434-2+A2 120 minutes BS EN 60754-1 BS EN 61034-2 +A1 BS EN 60332-3-24 & 3-25 BS EN 50200 PH30, PH60 & PH 120 BS 6389 … Read more

VNP-225

Enhanced- 2 Core 2.5 mm² with Earth (CPC), Harmonised Insulation Colour (Blue/Brown), Sheath (White)   Approved and Certified to Meet:   BS 5839-1 Clause 26.2e BS 7629-1 Enhanced 120 BS 8434-2+A2 120 minutes BS EN 60754-1 BS EN 61034-2 +A1 BS EN 60332-3-24 & 3-25 BS EN 50200 PH30, PH60 & PH 120 BS 6389 … Read more

VFP Platinum

NoBurn Platinum holds certifications from LPCB and BASEC, ensuring full compliance with the fire performance requirements of BS 7629-1 and the code of practice outlined in BS 5839 for ‘Standard 60’ fire cables used in fire systems. This premium product is exclusively manufactured in the United Kingdom.   The standards we comply with: LPCB & … Read more

C21218F

Multi-Conductor, Security, Audio, Control Cable, BMS, 6 Pairs/12 Conductors, 18 AWG, Stranded Bare Copper Conductor, Polypropylene Insulation, Shielded, Low Smoke Zero Halogen Jacket with Rip Cord   The standards we comply with: Environmental Suitability: Indoor-Riser, Indoor Flammability/Reaction to Fire: UL 1666 Riser: IEC 60332-1-2 UL Compliance: CM RoHS2 (2011/65/EU Compliant) UL Number E535337

C4216F-HFFR

Two Core Screened, 16 AWG, Bare Copper, Halogen Fire Flame Retardancy, Low Smoke Non-Halogen HFFR   The standards we comply with: Flammability to Fire: IEC 30332-3-24 Smoke Density: IEC 61034

C4214F-HFFR

Two Core Screened, 14 AWG, Bare Copper, Halogen Fire Flame Retardancy, Low Smoke Non-Halogen -HFFR   The standards we comply with: Flammability to Fire: IEC 30332-3-24 Smoke Density: IEC 61034

C2818F

Multi-Conductor, Security, Audio, Control Cable, BMS, 8 Conductor, 18 AWG, Stranded Bare Copper Conductor, Polypropylene Insulation, Shielded, Low Smoke Zero Halogen Jacket with 210D Nylon Rip Cord   The standards we comply with: Environmental Suitability: Indoor-Riser, Indoor Flammability/Reaction to Fire: UL 1666 Riser: IEC 60332-1-2 RoHS2 (2011/65/EU Compliant) UL Number E535337

C2618U-3P

Multi-Conductor, Security, Audio, Control Cable, BMS, 3 Pairs, 18 AWG, Stranded Bare Copper-twisted, Polyethylene Insulation, Unshielded, Low Smoke Zero Halogen Jacket with 210D Nylon Rip Cord   The standards we comply with: Environmental Suitability: Indoor-Riser, Indoor Reaction to Fire: IEC 60332-1-2 UL Compliance: CM RoHS2 (2011/65/EU Compliant) UL Number E535337

C2618F-3P

Multi-Conductor, Security, Audio, Control Cable, BMS, 3 Pairs, 18 AWG, Stranded Bare Copper-twisted, Polyethylene Insulation, Shielded, Low Smoke Zero Halogen Jacket with 210D Nylon Rip Cord   The standards we comply with: Environmental Suitability: Indoor-Riser, Indoor Reaction to Fire: IEC 60332-1-2 UL Compliance: CM RoHS2 (2011/65/EU Compliant) UL Number E535337